Erik Steen Hansen of DenmarkI am the person, who has done the trials/production using the Pineapple crusher. So far the crusher has worked very well!
-
Director Gerelkhuu of MongoliaYou are always welcome. Glad to work with your company and employees.
Coffee Processing Dairy Plant Machinery Automatic Mechanical Vapor Compression Evaporator

Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xVoltage | 380V | Application | Food Processing |
---|---|---|---|
Weight | 8900kg | Power Source | Natural Gas |
Process | Thermal | Power(W) | 55KW |
Material | SUS304 | Conctrol Type | PLC Full Automatc Control |
Application | Waste Water Treatment And Food Industry | External Dimension | 6m*4.5m*12m |
Processing Types | Coffee | Warranty | 12 Months |
High Light | dairy processing equipment,milk processing plant |
Automatic MVR evaporator for coffee processing line
Summary:
Mechanical vapor compression MVR or MVC (Mechanical Vapor Compression) evaporator, the principle is to use the secondary steam which is produced through compressing the steam by the steam compressor , secondary steam heat and temperature is increased by the compressor, steam compressed into the evaporator as the heat source, again makes the raw material liquid start evaporation, so there is no need to rely on external fresh steam, just need to rely on the evaporator system itself circulating to achieve the purpose of evaporation. Through the PLC control system, configuration software and engineering software to control the temperature, pressure, speed motor system, maintain stable, intelligent and efficient operation of the evaporator.
Performance characteristics and scope of application:
- No waste heat steam emissions, energy-saving effect is very significant, which is equivalent of 10 effect evaporator.
- Using this technology can achieve to countercurrent washing of secondary steam, therefore the dry matter content in condensed water is far lower than the number of evaporator.
- Using low temperature negative pressure evaporation (50-90 °C), help to prevent the degeneration resulted from high temperature evaporation.
- MVR evaporator is a substitute of traditional multi-effect falling-film evaporator, is based on single effect evaporator through the reuse of the secondary steam countercurrent washing and recompression. All material that applicable for single effect and multi-effect evaporator, are suitable for use in the MVR evaporator, technically have the substitutability. It has perfect characteristics of environmental protection and energy saving. Because of its significant energy-saving effect, MVR evaporator technology started rapid development in foreign countries at the beginning of 70's, now is widely used, which is used in industrial wastewater treatment and dairy, sugar, starch, alumina, papermaking, caprolactam, seawater desalination, coking plant (recovery of sulfur dioxide production sulfur ammonia), salt chemical industry, and other many production areas.
Technical parameters (evaporation according to the customer need to design)
Model | BYMVR-0.5 | BYMVR-1 | BYMVR-1.5 | BYMVR-2 | BYMVR-5 |
Evaporation capacity | 500kg/Hr | 1000kg/Hr | 1500kg/Hr | 2000kg/Hr | 5000kg/Hr |
Inlet saturated steam capacity(kg/Hr) | 500 | 1000 | 1500 | 2000 | 5000 |
Inlet saturation temperature (c) | 55.295 | 71.631 | 82.109 | 90 | 90 |
Outlet temperature (c) | 12.590 | 14.145 | 15.185 | 16.000 | 16.000 |
Outlet the saturation temperature (c) | 67.885 | 85.776 | 97.294 | 106.000 | 106.000 |
Inlet saturation pressure kPa (A) | 15.975 | 33.441 | 51.567 | 70.117 | 70.117 |
Inlet saturation pressure kPa (A) | 28.432 | 59.596 | 91.921 | 125.029 | 125.029 |
Compression ratio | 1.780 | 1.782 | 1.783 | 1.783 | 1.783 |
Motor power (kw) | 40 | 55 | 75 | 95 | 132 |
Outlet volume flow (m^3/s) | 0.795 | 0.7971 | 0.7985 | 0.7997 | 0.7997 |
exhaust velocity(m/s) | 22.736 | 22.795 | 22.837 | 22.87 | 22.87 |
Outlet volume flow (m^3/s) | 4X4X10 | 6X4.5X12 | 8X5.5X14 | 8X5.5X14 | 9.5X6X15 |